Addressable Smoke Detector features:
- Addressable-analog communication
- Low standby current for continuous monitoring (≤2.5mA)
- Two-wire connection
- Two LEDs (RED), blinks in normal condition and becomes stationary during fire
- Remote test from Panel
Standalone Battery Smoke Detector
1 × KSh 1,400.00
Reflective Optical smoke beam detector for addressable fire systems
1 × KSh 28,000.00 Subtotal: KSh 29,400.00
Availability:In Stock!
KSh 3,200.00
The installation of the detector uses a high-precision symmetrical infrared laser, which has good long-distance focusing, good consistency, and long-term stability and reliability; the appearance is exquisite and practical, with a variety of connection terminals, and the connection is flexible and convenient. It can be connected and used with the AW-FP100/128/200/2166 series panels (by model).
1.Supports isolation function
2. Supports infrared remote control operation.
3. Suitable for all larger warehouses or more open protection places
4.Meets all requirements of the latest EN54-12 standard
5.Optical distance can reach to maximum 160m, minimum 5m
24V Conventional Fire alarm belFire alarm bell, a fire alarm device, generally used in public areas. In the event of an emergency situation is controlled by the alarm controller to trigger an alarm, one for each region under normal circumstances, be used for fire alarms, good warning sound effects.Fire alarm bell generally come in 6 inch and 8 inch Specification.
Fire alarm bell internally by a 24V DC motor driven by the crankshaft and connecting rod bells, no relays work, work current, high reliability.
Fire alarm for supporting specific products and linkage fire alarm systems, when the system recognizes fire broke out by linkage control equipment to the scene.
| Working voltage | 20VDC to 28VDC | 20VDC to 28VDC |
| Work current @24VDC | ≤50mA | ≤50mA |
| Volume(dB) @1m | ≥98dB | ≥100dB |
| Dimensions | 150mm*150mm*60mm | 200mm*200mm*67.5mm |
| Net Weight | 600g | 1060g |
smoke with fixed temperature and rate-of-rise heat detector. The detector uses an optical sensing chamber to detect smoke and a fixed-temperature heat sensor to detect heat from fire. It is designed to provide open area protection . The red LED on the detector provides a local 360°visible alarm indication. The detector that initiated the alarm condition will have its red LED latched until reset by panel.
Asenware Addressable Fire Alarm Annunciator Panel is a 24 Zone Board, which can be configured at the site as per,the Fire Alarm System Layout drawing. It includes keyboard, Power LED and buzzer. Fire Alarm Annunciator Panel can extensions 24 zone board. it can be used with AW-FP100 Series Addressable Fire Alarm Control Panel.
We have the best security system solutions for you. Intelligent security for the modern world
©2026. Sparsec Systems Ltd. All Rights Reserved.