Fire-resistant cables can maintain normal operation for a certain period under flame burning conditions and maintain the line’s integrity. The amount of smoke produced when burning fire-resistant cable is less, especially with refractory materials, making fire-resistant flame retardant performance, especially in the case of burning, accompanied by water sprinkling and fire fighting,
1.5MM Fire Resistant Cables 100M
Availability:In Stock!
Fire-resistant cables can maintain normal operation for a certain period under flame burning conditions and maintain the line’s integrity. The amount of smoke produced when burning fire-resistant cable is less, especially with refractory materials, making fire-resistant flame retardant performance, especially in the case of burning, accompanied by water sprinkling and fire fighting.
KSh 5,800.00
CompareBased on 0 reviews
Be the first to review “1.5MM Fire Resistant Cables 100M” Cancel reply
Related products
-
Fire Alarm Systems
Conventional Fire Alarm Strobe Sounder Beacon
0 out of 5(0)Conventional Strobe Sounder Beacon can give audible and visual alarms after being connected to a DC24V power supply. It can be used with a bus-type fire alarm control panel through an output module. After receiving a start command given by the fire alarm control panel following an accident, the output module will start the Sounder Beacon. After that, the Sounder Beacon will give a dazzling visual alarm signal and a harsh audible alarm signal to remind the persons on the scene of the accident of the fact that a fire has occurred on the site quickly and the necessity to take related evacuation measures, thus preventing the fire accident from becoming a major one.
The Strobe Sounder Beacon may be used to give audible alarms and visual alarms at the scenes of accidents.It is applicable to places like high-rise residential buildings, public places, hotels, amusement buildings, factories, shopping centers, hospitals, schools, office buildings and stock exchanges, and particularly to the places with a low visibility or the possibility of generation of smoke.
Strobe Sounder Beacon feature:
Meet both EN54-3 and EN54 -23.
Designed with an upper cover and a lower cover and installed on an independent base, it can be installed, debugged and maintained conveniently.
Suitable for wall and ceiling mount application.
Providing 16 tones.
Highly efficient LED technology and specially designed lens.
Light output synchronization.SKU: n/a -
Fire Alarm Systems
AW-CMC2166-6 Manual push station
0 out of 5(0)Conventional Manual Call Point is a safety device used in fire alarm and emergency notification systems. It allows individuals to manually activate an alarm signal in the event of a fire or other emergency situation. Here’s a description of the AW-CMC2166-6 Conventional Manual Call Point:
Product Name: AW-CMC2166-6 Conventional Manual Call Point
Key Features and Characteristics:
- Emergency Activation: The primary function of the manual call point is to provide a means for individuals to manually initiate an alarm in case of a fire or other emergency. When activated, it sends a signal to the fire alarm control panel to trigger the alarm and initiate the appropriate emergency response.
- Resettable: After activation, the manual call point can usually be reset using a key or tool provided with the device. This ensures that the alarm system can be returned to normal operation once the emergency situation is resolved.
- Break Glass or Push Button: Manual call points are typically available in two main types: break glass and push-button. Break glass models require breaking a glass element to activate the alarm, while push-button models are activated by pressing a button.
- Visible Activation Indicator: Many manual call points feature a visible indicator (often a colored flag or LED) that shows when the device has been activated. This helps responders identify the location of the alarm activation quickly.
- Test Function: Manual call points often include a test function, allowing users to verify that the device is operational without triggering a full alarm.
- Mounting: These devices are designed for wall mounting in strategic locations throughout a building or facility. They are typically installed near exits, stairwells, and other areas where people can easily access them in case of an emergency.
- Weatherproof Options: Some manual call points are designed to be weatherproof or suitable for outdoor use, making them suitable for use in a variety of environments.
- Compatibility: The AW-CMC2166-6 is part of a conventional fire alarm system. It is compatible with other components of the system, such as smoke detectors, heat detectors, and the fire alarm control panel.
- Tamper-Resistant: Manual call points are often designed to deter tampering or unauthorized activation. They may have security features to prevent false alarms.
- Compliance: Manual call points are typically manufactured to meet relevant fire safety standards and regulations, ensuring their reliability and performance in emergency situations.
SKU: n/a -
Fire Alarm Systems
Conventional Reflective Optical Beam Smoke Detector
0 out of 5(0)AW-D130C is a Linear Beam Smoke Detector with telescope-style dual-mirrors structure; its professional mirror design ensures good product performance and signal stability at a distance of up to 160m. With a very powerful 32-bit MCU as the controller, AW-D130C plays high performance, responds more sensitively, controls more quickly, and can detect subtle changes.
Features
1. High-transparency telescope structure
2. Easy debugging, accurate and fast alignment, intelligent and fast calibration;
3.High quality, durability and highly sensitive sensor
4. Automatic compensation, improves the ability to resist dust and vibration interference and reduces false alarms.
5.Optical distance can reach to maximum 160m, minimum 5mSKU: n/a -
Fire Alarm Systems
Asenware Fire Alarm Heat Detector
0 out of 5(0)Two LEDs on each detector provide a local 360? visible alarm indication. They die out when the ambient temperature does not reach the alarm value. If the temperature reaches the alarm value, then the detector enters alarm mode and LEDs light. Operating voltage range: 9 to 28 VDC volts non-polarized maximum alarm current(led on): 48ma@24vdc operating temperature range: -10c to 70c fix temperature range: 60c rate of rise alarm: 7.1c/5s height: 31.78mm installed in base diameter: 99.45mm
SKU: n/a

Hikvision Video Door phone / Intercom Kit